← Back to product pageFree data sheet, no subscription
heatpumpdatabase
Product data sheetheatpumpdatabase.com

Acond Grandis-N

Model code: N SP
✓ BUS eligible✓ MCS listedAir Source (ASHP)ResidentialHeating only
Heating capacity
3.54 kW
SCOP
5.38
W35
COP
5.54
A7/W35
Max flow temp
70°C
Sound power
46.1 dB(A)
Refrigerant
R290

Boiler Upgrade Scheme

✓ BUS eligible

Listed on the Ofgem BUS Product Eligibility List (24 Sep 2026).

PEL certificate: 037-0102-22-1

Grant also needs an MCS-certified installer and a qualifying system design.

MCS certification

✓ MCS listed

Certificate: 037-0102-22-1

General
Heat pump typeAir Source (ASHP)
ApplicationResidential
RefrigerantR290
ModeHeating only
Heating performance
Heating capacity3.54 kW
Max heating output (low temp)5.3 kW at A-7/W35
COP (heating)5.54 at A7/W35
SCOP (heating)5.38 at W35
Heating flow temperature20–70 °C
Electrical, acoustic and physical
Electrical supply220-240V (Single Phase)
Sound power level46.1 dB(A) (Sound Power LW(A))
Dimensions (H×W×D)759 × 1128 × 542 mm
Operational Weight110 kg

Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.