← Back to product pageFree data sheet, no subscription
heatpumpdatabase
Product data sheetheatpumpdatabase.com

Advantix (MAXA) i-32V5 (current)

Model code: i-32V5/KA/14T
✓ BUS eligible✓ MCS listedAir Source (ASHP)ResidentialHeating & cooling
Heating capacity
15.2 kW
SCOP
4.5
W35
COP
4.9
A7/W35
Max flow temp
60°C
Sound power
68 dB(A)
Refrigerant
R32

Boiler Upgrade Scheme

✓ BUS eligible

Listed on the Ofgem BUS Product Eligibility List (24 Sep 2026).

PEL certificate: ICIM-PDC-000075-00-04

Grant also needs an MCS-certified installer and a qualifying system design.

MCS certification

✓ MCS listed

Certificate: ICIM-PDC-000075-00-04

General
Heat pump typeAir Source (ASHP)
ApplicationResidential
RefrigerantR32
ModeHeating & cooling
Heating performance
Heating capacity15.2 kW
Max heating output (low temp)14.6 kW at A7/W45
COP (heating)4.9 at A7/W35
SCOP (heating)4.5 at W35
Operating range (air)-20 to 40 °C
Heating flow temperature25–60 °C
Cooling performance
Cooling capacity14.7 kW
Max cooling output (high temp)11.5 kW at A35/W7
EER (cooling)3.3 at A35/W7
SEER (cooling)4.8 at W7
Cooling flow temperature5–25 °C
Electrical, acoustic and physical
Electrical supply380-415V (Three Phase)
Sound power level68 dB(A) (Sound Power LW(A))
Dimensions (H×W×D)1409 × 1044 × 455 mm
Operational Weight136 kg

Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.