← Back to product pageFree data sheet, no subscription
heatpumpdatabase
Product data sheetheatpumpdatabase.com

Alpha Innotec alira LWD

Model code: LWD 70A
✓ BUS eligibleAir Source (ASHP)ResidentialHeating only
Heating capacity
10.5 kW
COP
4.3
A7/W35
Max flow temp
62°C
Sound power
57 dB(A)
Refrigerant
R290

Boiler Upgrade Scheme

✓ BUS eligible

Listed on the Ofgem BUS Product Eligibility List (24 Sep 2026).

PEL certificate: 041-K001-21 a

Grant also needs an MCS-certified installer and a qualifying system design.

MCS certification

No MCS listing recorded.

General
Heat pump typeAir Source (ASHP)
ApplicationResidential
RefrigerantR290
ModeHeating only
Heating performance
Heating capacity10.5 kW
Max heating output (low temp)6.3 kW at A-7/W35
COP (heating)4.3 at A7/W35
Operating range (air)-20 to 35 °C
Heating flow temperature20–62 °C
Electrical, acoustic and physical
Electrical supply380-415V (Three Phase)
Sound power level57 dB(A) (Sound Power LW(A))
Dimensions (H×W×D)1320 × 930 × 505 mm
Operational Weight146 kg

Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.