Product data sheetheatpumpdatabase.com

Alpha Innotec SWC
Model code: SWC 102(H)(K)3
✓ MCS listedGround Source (GSHP)ResidentialHeating & cooling
Heating capacity
9.34 kW
COP
5.05
B0/W35
Max flow temp
60°C
Sound power
44 dB(A)
Refrigerant
R410A
Boiler Upgrade Scheme
Not found on the Ofgem BUS Product Eligibility List.
MCS certification
✓ MCS listed
| General | |
|---|---|
| Heat pump type | Ground Source (GSHP) |
| Application | Residential |
| Refrigerant | R410A |
| Mode | Heating & cooling |
| Heating performance | |
| Heating capacity | 9.34 kW |
| Max heating output (low temp) | 9.34 kW at B0/W35 |
| COP (heating) | 5.05 at B0/W35 |
| Operating range (air) | -5 to 25 °C |
| Heating flow temperature | 20–60 °C |
| Cooling performance | |
| Cooling capacity | 8.6 kW |
| Electrical, acoustic and physical | |
| Power input | 1.87 kW |
| Electrical supply | 380-415V (Three Phase) |
| Sound power level | 44 dB(A) (Sound Power LW(A)) |
| Dimensions (H×W×D) | 1500 × 598 × 665 mm |
| Operational Weight | 180 kg |
Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.