Product data sheetheatpumpdatabase.com
AS Thermal ME-AMH-14R1
Model code: ME-AMH-14R1
Air Source (ASHP)ResidentialHeating & cooling
Heating capacity
14.66 kW
COP
4.98
A7/W35
Max flow temp
60°C
Sound power
57 dB(A)
Refrigerant
R32
Boiler Upgrade Scheme
Not found on the Ofgem BUS Product Eligibility List.
MCS certification
No MCS listing recorded.
| General | |
|---|---|
| Heat pump type | Air Source (ASHP) |
| Application | Residential |
| Refrigerant | R32 |
| Mode | Heating & cooling |
| Heating performance | |
| Heating capacity | 14.66 kW |
| Max heating output (low temp) | 14.42 kW at A7/W45 |
| COP (heating) | 4.98 at A7/W35 |
| Operating range (air) | -20 to 35 °C |
| Heating flow temperature | 20–60 °C |
| Cooling performance | |
| Cooling capacity | 14.3 kW |
| Max cooling output (high temp) | 14.05 kW at A35/W18 |
| EER (cooling) | 3.15 at A35/W7 |
| Cooling flow temperature | 5–25 °C |
| Electrical, acoustic and physical | |
| Power input | 6.2 kW |
| Electrical supply | 220-240V (Single Phase) |
| Sound power level | 57 dB(A) (Sound Pressure) |
| Dimensions (H×W×D) | 950 × 1155 × 500 mm |
| Operational Weight | 126 kg |
Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.