← Back to product pageFree data sheet, no subscription
heatpumpdatabase
Product data sheetheatpumpdatabase.com

Atlantic Ixtra M

Model code: Ixtra M TRI 17
Air Source (ASHP)ResidentialHeating only
Atlantic Ixtra M
Heating capacity
17 kW
SCOP
4.19
W35
COP
3.23
A7/W35
Max flow temp
60°C
Sound power
52 dB(A)
Refrigerant
R452B

Boiler Upgrade Scheme

Not found on the Ofgem BUS Product Eligibility List.

MCS certification

No MCS listing recorded.

General
Heat pump typeAir Source (ASHP)
ApplicationResidential
RefrigerantR452B
ModeHeating only
Heating performance
Heating capacity17 kW
Max heating output (low temp)13.64 kW at A-7/W55
COP (heating)3.23 at A7/W35
SCOP (heating)4.19 at W35
Heating flow temperatureup to 60 °C
Electrical, acoustic and physical
Electrical supply380-415V (Three Phase)
Sound power level52 dB(A) (Sound Power LW(A))
Dimensions (H×W×D)1723 × 953 × 816 mm
Operational Weight250 kg

Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.