Product data sheetheatpumpdatabase.com

Atlantic Loria Duo
Model code: LORIA DUO 6010
Air Source (ASHP)ResidentialHeating only

Heating capacity
10.42 kW
COP
4.4
A7/W35
Max flow temp
55°C
Sound power
69 dB(A)
Refrigerant
R410A
Boiler Upgrade Scheme
Not found on the Ofgem BUS Product Eligibility List.
MCS certification
No MCS listing recorded.
| General | |
|---|---|
| Heat pump type | Air Source (ASHP) |
| Application | Residential |
| Refrigerant | R410A |
| Mode | Heating only |
| Heating performance | |
| Heating capacity | 10.42 kW |
| Max heating output (low temp) | 7.94 kW at A-7/W35 |
| COP (heating) | 4.4 at A7/W35 |
| Operating range (air) | -20 to 35 °C |
| Heating flow temperature | up to 55 °C |
| Electrical, acoustic and physical | |
| Electrical supply | 220-240V (Single Phase) |
| Sound power level | 69 dB(A) (Sound Power LW(A)) |
| Dimensions (H×W×D) | 830 × 900 × 400 mm |
| Operational Weight | 60 kg |
Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.