← Back to product pageFree data sheet, no subscription
heatpumpdatabase
Product data sheetheatpumpdatabase.com

Beretta (Riello) HYDRO UNIT P

Model code: HYDRO UNIT P 006
✓ BUS eligible✓ MCS listedAir Source (ASHP)ResidentialHeating & cooling
Heating capacity
5.8 kW
SCOP
4.82
W35
COP
4.9
A7/W35
Max flow temp
75°C
Sound power
50 dB(A)
Refrigerant
R290

Boiler Upgrade Scheme

✓ BUS eligible

Listed on the Ofgem BUS Product Eligibility List (24 Sep 2026).

PEL certificate: 011-1W0627

Grant also needs an MCS-certified installer and a qualifying system design.

MCS certification

✓ MCS listed

Certificate: 011-1W0627

General
Heat pump typeAir Source (ASHP)
ApplicationResidential
RefrigerantR290
ModeHeating & cooling
Heating performance
Heating capacity5.8 kW
Max heating output (low temp)5.5 kW at A7/W45
COP (heating)4.9 at A7/W35
SCOP (heating)4.82 at W35
Operating range (air)-20 to 40 °C
Heating flow temperatureup to 75 °C
Cooling performance
Cooling capacity4.6 kW
Max cooling output (high temp)4.6 kW at A35/W7
EER (cooling)3.15 at A35/W7
SEER (cooling)5.34 at W7
Electrical, acoustic and physical
Electrical supply220-240V (Single Phase)
Sound power level50 dB(A) (Sound Power LW(A))
Dimensions (H×W×D)927 × 946 × 372 mm
Operational Weight84 kg

Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.