← Back to product pageFree data sheet, no subscription
heatpumpdatabase
Product data sheetheatpumpdatabase.com

Carrier Aquasnap 30AWH-R (R32)

Model code: 30AWH010R
Air Source (ASHP)ResidentialHeating & cooling
Carrier Aquasnap 30AWH-R (R32)
Heating capacity
10 kW
SCOP
4.98
W35
COP
4.5
A7/W35
Max flow temp
62°C
Sound power
66 dB(A)
Refrigerant
R32

Boiler Upgrade Scheme

Not found on the Ofgem BUS Product Eligibility List.

MCS certification

No MCS listing recorded.

General
Heat pump typeAir Source (ASHP)
ApplicationResidential
RefrigerantR32
ModeHeating & cooling
Heating performance
Heating capacity10 kW
Max heating output (low temp)9.5 kW at A7/W55
COP (heating)4.5 at A7/W35
SCOP (heating)4.98 at W35
Operating range (air)-25 to 50 °C
Heating flow temperatureup to 62 °C
Cooling performance
Cooling capacity8 kW
Max cooling output (high temp)8 kW at A35/W7
EER (cooling)3 at A35/W7
SEER (cooling)4.89 at W7
Electrical, acoustic and physical
Electrical supply220-240V (Single Phase)
Sound power level66 dB(A) (Sound Power LW(A))
Dimensions (H×W×D)875 × 1335 × 475 mm
Operational Weight126 kg

Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.