← Back to product pageFree data sheet, no subscription
heatpumpdatabase
Product data sheetheatpumpdatabase.com

Climer Airys Compact

Model code: ACP12T
✓ BUS eligible✓ MCS listedAir Source (ASHP)ResidentialHeating & cooling
Heating capacity
11.8 kW
SCOP
4.5
W35
COP
4.3
A7/W35
Sound power
62 dB(A)
Refrigerant
R32

Boiler Upgrade Scheme

✓ BUS eligible

Listed on the Ofgem BUS Product Eligibility List (24 Sep 2026).

PEL certificate: ICIM-PDC-000202-00-01

Grant also needs an MCS-certified installer and a qualifying system design.

MCS certification

✓ MCS listed

Certificate: ICIM-PDC-000202-00-01

General
Heat pump typeAir Source (ASHP)
ApplicationResidential
RefrigerantR32
ModeHeating & cooling
Heating performance
Heating capacity11.8 kW
Max heating output (low temp)11.5 kW at A7/W45
COP (heating)4.3 at A7/W35
SCOP (heating)4.5 at W35
Cooling performance
Cooling capacity11.6 kW
Max cooling output (high temp)8.5 kW at A35/W7
EER (cooling)3.1 at A35/W7
SEER (cooling)4.4 at W7
Electrical, acoustic and physical
Power input5.1 kW
Electrical supply380-415V (Three Phase)
Sound power level62 dB(A) (Sound Power LW(A))
Dimensions (H×W×D)936 × 1047 × 455 mm
Operational Weight96 kg

Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.