Product data sheetheatpumpdatabase.com

Cool Energy inverTech iVT
Model code: CE-iVT18-3PH
Air Source (ASHP)ResidentialHeating & cooling
Heating capacity
8.56–18.6 kW
SCOP
4.87
W35
Max flow temp
75°C
Sound power
59 dB(A)
Refrigerant
R410A
Boiler Upgrade Scheme
Not found on the Ofgem BUS Product Eligibility List.
MCS certification
No MCS listing recorded.
| General | |
|---|---|
| Heat pump type | Air Source (ASHP) |
| Application | Residential |
| Refrigerant | R410A |
| Mode | Heating & cooling |
| Heating performance | |
| Heating capacity | 8.56–18.6 kW |
| Max heating output (low temp) | 14.21 kW at A-3/W45 |
| SCOP (heating) | 4.87 at W35 |
| Operating range (air) | -20 to 45 °C |
| Heating flow temperature | up to 75 °C |
| Cooling performance | |
| Cooling capacity | 13.11 kW |
| Max cooling output (high temp) | 13.11 kW at A25/W7 |
| Electrical, acoustic and physical | |
| Electrical supply | 380-415V (Three Phase) |
| Sound power level | 59 dB(A) (Sound Power LW(A)) |
| Dimensions (H×W×D) | 1355 × 1110 × 475 mm |
| Operational Weight | 124 kg |
Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.