Product data sheetheatpumpdatabase.com
CTC CombiAir 6M
Model code: 589350001
✓ MCS listedAir Source (ASHP)ResidentialHeating & cooling
Heating capacity
4.64 kW
COP
5.32
A7/W35
Max flow temp
58°C
Sound power
50 dB(A)
Refrigerant
R410A
Boiler Upgrade Scheme
Not found on the Ofgem BUS Product Eligibility List.
MCS certification
✓ MCS listed
| General | |
|---|---|
| Heat pump type | Air Source (ASHP) |
| Application | Residential |
| Refrigerant | R410A |
| Mode | Heating & cooling |
| Heating performance | |
| Heating capacity | 4.64 kW |
| Max heating output (low temp) | 4.64 kW at A-7/W35 |
| COP (heating) | 5.32 at A7/W35 |
| Operating range (air) | from -20 °C |
| Heating flow temperature | up to 58 °C |
| Cooling performance | |
| Cooling capacity | 7.98 kW |
| Max cooling output (high temp) | 5.87 kW at A27/W7 |
| EER (cooling) | 2.16 at A35/W7 |
| Electrical, acoustic and physical | |
| Electrical supply | 220-240V (Single Phase) |
| Sound power level | 50 dB(A) (Sound Power LW(A)) |
| Dimensions (H×W×D) | 791 × 993 × 364 mm |
| Operational Weight | 67 kg |
Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.