Daikin Altherma 3 H (EPGA-D)

Model code: EPGA16DV7
✓ BUS eligible✓ MCS listedAir Source (ASHP)ResidentialHeating & cooling
Heating capacity
16.5 kW
SCOP
4.56
W35
COP
4.78
A7/W35
Max flow temp
60°C
Sound power
66 dB(A)
Refrigerant
R32

Boiler Upgrade Scheme

✓ BUS eligible

Listed on the Ofgem BUS Product Eligibility List (24 Sep 2026).

PEL certificate: 011-1W0323_1; 011-1W0323_2; 011-1W0323_3; 011-1W0323_4; 011-1W0323_5; 011-1W0324

Grant also needs an MCS-certified installer and a qualifying system design.

MCS certification

✓ MCS listed

Certificate: 011-1W0323_1; 011-1W0323_2; 011-1W0323_3; 011-1W0323_4; 011-1W0323_5; 011-1W0324

General
Heat pump typeAir Source (ASHP)
ApplicationResidential
RefrigerantR32
ModeHeating & cooling
Heating performance
Heating capacity16.5 kW
Max heating output (low temp)15.6 kW at A7/W45
COP (heating)4.78 at A7/W35
SCOP (heating)4.56 at W35
Operating range (air)-28 to 35 °C
Heating flow temperature18–60 °C
Cooling performance
Cooling capacity11.9 kW
Max cooling output (high temp)11.9 kW at A35/W7
EER (cooling)2.99 at A35/W7
Electrical, acoustic and physical
Electrical supply220-240V (Single Phase)
Sound power level66 dB(A) (Sound Power LW(A))
Dimensions (H×W×D)1440 × 1160 × 380 mm
Operational Weight143 kg

Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.