Product data sheetheatpumpdatabase.com

Daikin Altherma 3 H HT
Model code: ETBX16E6V + EPRA18DV3
✓ BUS eligible✓ MCS listedAir Source (ASHP)ResidentialHeating & cooling
Heating capacity
12.11 kW
SCOP
4.57
W35
COP
4.86
A7/W35
Max flow temp
70°C
Sound power
54 dB(A)
Refrigerant
R32
Boiler Upgrade Scheme
✓ BUS eligible
Listed on the Ofgem BUS Product Eligibility List (24 Sep 2026).
PEL certificate: 011-1W0353_01
Grant also needs an MCS-certified installer and a qualifying system design.
MCS certification
✓ MCS listed
Certificate: EPRA18DV3 / ETBX16E6V
| General | |
|---|---|
| Heat pump type | Air Source (ASHP) |
| Application | Residential |
| Refrigerant | R32 |
| Mode | Heating & cooling |
| Heating performance | |
| Heating capacity | 12.11 kW |
| Max heating output (low temp) | 12.11 kW at A-2/W55 |
| COP (heating) | 4.86 at A7/W35 |
| SCOP (heating) | 4.57 at W35 |
| Operating range (air) | -28 to 35 °C |
| Heating flow temperature | 18–70 °C |
| Cooling performance | |
| Cooling capacity | 12.46 kW |
| Max cooling output (high temp) | 8.86 kW at A35/W7 |
| EER (cooling) | 2.68 at A35/W7 |
| Cooling flow temperature | 5–25 °C |
| Electrical, acoustic and physical | |
| Electrical supply | 220-240V (Single Phase) |
| Sound power level | 54 dB(A) (Sound Power LW(A)) |
| Dimensions (H×W×D) | 990 × 1270 × 460 mm |
| Operational Weight | 146 kg |
Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.