← Back to product pageFree data sheet, no subscription
heatpumpdatabase
Product data sheetheatpumpdatabase.com

Daikin Altherma 3 M

Model code: EBLA16DV3
✓ MCS listedAir Source (ASHP)ResidentialHeating & cooling
Heating capacity
16 kW
SCOP
4.69
W35
COP
4.53
A7/W35
Max flow temp
60°C
Sound power
62 dB(A)
Refrigerant
R32

Boiler Upgrade Scheme

Not found on the Ofgem BUS Product Eligibility List.

MCS certification

✓ MCS listed

Certificate: EBLA16DAV37

General
Heat pump typeAir Source (ASHP)
ApplicationResidential
RefrigerantR32
ModeHeating & cooling
Heating performance
Heating capacity16 kW
Max heating output (low temp)16 kW at A7/W45
COP (heating)4.53 at A7/W35
SCOP (heating)4.69 at W35
Operating range (air)-25 to 35 °C
Heating flow temperature9–60 °C
Cooling performance
Cooling capacity15.3 kW
Max cooling output (high temp)15.3 kW at A35/W18
EER (cooling)3.06 at A35/W7
SEER (cooling)5.59 at Not stated
Cooling flow temperature5–22 °C
Electrical, acoustic and physical
Electrical supply220-240V (Single Phase)
Sound power level62 dB(A) (Sound Power LW(A))
Dimensions (H×W×D)870 × 1380 × 460 mm
Operational Weight149 kg

Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.