Product data sheetheatpumpdatabase.com

Daikin Altherma 3 M
Model code: EBLA16DA3V37
✓ BUS eligibleAir Source (ASHP)ResidentialHeating & cooling
Heating capacity
16 kW
SCOP
4.69
W35
COP
4.53
A7/W35
Max flow temp
60°C
Sound power
62 dB(A)
Refrigerant
R32
Boiler Upgrade Scheme
✓ BUS eligible
Listed on the Ofgem BUS Product Eligibility List (24 Sep 2026).
PEL certificate: 011-1W0566_02
Grant also needs an MCS-certified installer and a qualifying system design.
MCS certification
No MCS listing recorded.
| General | |
|---|---|
| Heat pump type | Air Source (ASHP) |
| Application | Residential |
| Refrigerant | R32 |
| Mode | Heating & cooling |
| Heating performance | |
| Heating capacity | 16 kW |
| Max heating output (low temp) | 16 kW at A7/W45 |
| COP (heating) | 4.53 at A7/W35 |
| SCOP (heating) | 4.69 at W35 |
| Heating flow temperature | 15–60 °C |
| Cooling performance | |
| Cooling capacity | 15.3 kW |
| Max cooling output (high temp) | 14 kW at A35/W7 |
| EER (cooling) | 3.06 at A35/W7 |
| Cooling flow temperature | 5–22 °C |
| Electrical, acoustic and physical | |
| Electrical supply | 220-240V (Single Phase) |
| Sound power level | 62 dB(A) (Sound Power LW(A)) |
| Dimensions (H×W×D) | 870 × 1380 × 460 mm |
| Operational Weight | 149 kg |
Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.