← Back to product pageFree data sheet, no subscription
heatpumpdatabase
Product data sheetheatpumpdatabase.com

Daikin Altherma 3 M

Model code: EDLA14DA3V3
✓ BUS eligibleAir Source (ASHP)ResidentialHeating only
Heating capacity
12.5 kW
SCOP
4.62
W35
COP
4.87
A7/W35
Max flow temp
60°C
Sound power
62 dB(A)
Refrigerant
R32

Boiler Upgrade Scheme

✓ BUS eligible

Listed on the Ofgem BUS Product Eligibility List (24 Sep 2026).

PEL certificate: 011-1W0425_06

Grant also needs an MCS-certified installer and a qualifying system design.

MCS certification

No MCS listing recorded.

General
Heat pump typeAir Source (ASHP)
ApplicationResidential
RefrigerantR32
ModeHeating only
Heating performance
Heating capacity12.5 kW
Max heating output (low temp)12.5 kW at A7/W45
COP (heating)4.87 at A7/W35
SCOP (heating)4.62 at W35
Heating flow temperature15–60 °C
Electrical, acoustic and physical
Electrical supply220-240V (Single Phase)
Sound power level62 dB(A) (Sound Power LW(A))
Dimensions (H×W×D)870 × 1380 × 460 mm
Operational Weight149 kg

Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.