← Back to product pageFree data sheet, no subscription
heatpumpdatabase
Product data sheetheatpumpdatabase.com

Daikin Altherma 3 R

Model code: ERLA11DAW1
Air Source (ASHP)ResidentialHeating & cooling
Heating capacity
10.6 kW
SCOP
4.72
W35
COP
4.83
A7/W35
Max flow temp
60°C
Sound power
62 dB(A)
Refrigerant
R32

Boiler Upgrade Scheme

Not found on the Ofgem BUS Product Eligibility List.

MCS certification

No MCS listing recorded.

General
Heat pump typeAir Source (ASHP)
ApplicationResidential
RefrigerantR32
ModeHeating & cooling
Heating performance
Heating capacity10.6 kW
Max heating output (low temp)10.6 kW at A7/W35
COP (heating)4.83 at A7/W35
SCOP (heating)4.72 at W35
Operating range (air)from -25 °C
Heating flow temperatureup to 60 °C
Cooling performance
Cooling capacity12 kW
Max cooling output (high temp)11.2 kW at A35/W7
EER (cooling)3.26 at A35/W7
SEER (cooling)5.92 at EN 14825 (flow temp not stated)
Electrical, acoustic and physical
Electrical supply380-415V (Three Phase)
Sound power level62 dB(A) (Sound Power LW(A))
Dimensions (H×W×D)870 × 1100 × 460 mm
Operational Weight101 kg

Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.