Product data sheetheatpumpdatabase.com

Dimplex LA S-TU/S-TUR
Model code: LA 1118CP
Air Source (ASHP)ResidentialHeating & cooling
Heating capacity
11.2 kW
COP
5.6
A7/W35
Max flow temp
65°C
Sound power
49 dB(A)
Refrigerant
R290
Boiler Upgrade Scheme
Not found on the Ofgem BUS Product Eligibility List.
MCS certification
No MCS listing recorded.
| General | |
|---|---|
| Heat pump type | Air Source (ASHP) |
| Application | Residential |
| Refrigerant | R290 |
| Mode | Heating & cooling |
| Heating performance | |
| Heating capacity | 11.2 kW |
| Max heating output (low temp) | 11.2 kW at A-7/W35 |
| COP (heating) | 5.6 at A7/W35 |
| Operating range (air) | -22 to 35 °C |
| Heating flow temperature | 18–65 °C |
| Cooling performance | |
| Cooling capacity | 8 kW |
| Max cooling output (high temp) | 8 kW at A35/W18 |
| EER (cooling) | 3.6 at A27/W18 |
| Cooling flow temperature | 12–20 °C |
| Electrical, acoustic and physical | |
| Electrical supply | 380-415V (Three Phase) |
| Sound power level | 49 dB(A) (Sound Power LW(A)) |
| Dimensions (H×W×D) | 1107 × 1418 × 598 mm |
| Operational Weight | 213 kg |
Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.