Product data sheetheatpumpdatabase.com

Dimplex LA TU-2/ TBS
Model code: LA 3860
Air Source (ASHP)ResidentialHeating only
Heating capacity
43.4 kW
COP
4.5
A7/W35
Max flow temp
62°C
Sound power
78 dB(A)
Refrigerant
R407C
Boiler Upgrade Scheme
Not found on the Ofgem BUS Product Eligibility List.
MCS certification
No MCS listing recorded.
| General | |
|---|---|
| Heat pump type | Air Source (ASHP) |
| Application | Residential |
| Refrigerant | R407C |
| Mode | Heating only |
| Heating performance | |
| Heating capacity | 43.4 kW |
| Max heating output (low temp) | 38 kW at A-7/W35 |
| COP (heating) | 4.5 at A7/W35 |
| Operating range (air) | -22 to 40 °C |
| Heating flow temperature | 22–62 °C |
| Electrical, acoustic and physical | |
| Power input | 26.4 kW |
| Electrical supply | 380-415V (Three Phase) |
| Sound power level | 78 dB(A) (Sound Power LW(A)) |
| Dimensions (H×W×D) | 2300 × 1900 × 1000 mm |
| Operational Weight | 870 kg |
Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.