← Back to product pageFree data sheet, no subscription
heatpumpdatabase
Product data sheetheatpumpdatabase.com

Dimplex SI

Model code: SI 26TU
✓ BUS eligible✓ MCS listedGround Source (GSHP)CommercialHeating only
Heating capacity
26.7 kW
COP
5.1
B0/W35
Max flow temp
62°C
Sound power
57 dB(A)
Refrigerant
R410A

Boiler Upgrade Scheme

✓ BUS eligible

Listed on the Ofgem BUS Product Eligibility List (24 Sep 2026).

PEL certificate: MCS HP0017/35

Grant also needs an MCS-certified installer and a qualifying system design.

MCS certification

✓ MCS listed

Certificate: MCS HP0017/35

General
Heat pump typeGround Source (GSHP)
ApplicationCommercial
RefrigerantR410A
ModeHeating only
Heating performance
Heating capacity26.7 kW
Max heating output (low temp)22.5 kW at B-5/W45
COP (heating)5.1 at B0/W35
Operating range (air)-5 to 25 °C
Heating flow temperature20–62 °C
Electrical, acoustic and physical
Power input10 kW
Electrical supply380-415V (Three Phase)
Sound power level57 dB(A) (Sound Power LW(A))
Dimensions (H×W×D)880 × 1000 × 750 mm
Operational Weight275 kg

Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.