Product data sheetheatpumpdatabase.com

Dimplex System C
Model code: LA 4060CP
✓ BUS eligibleAir Source (ASHP)ResidentialHeating & cooling
Heating capacity
19–41.8 kW
SCOP
4.7
W35
COP
4.6
A7/W35
Max flow temp
70°C
Sound power
54 dB(A)
Refrigerant
R290
Boiler Upgrade Scheme
✓ BUS eligible
Listed on the Ofgem BUS Product Eligibility List (24 Sep 2026).
PEL certificate: MCS HP0017/48
Grant also needs an MCS-certified installer and a qualifying system design.
MCS certification
No MCS listing recorded.
| General | |
|---|---|
| Heat pump type | Air Source (ASHP) |
| Application | Residential |
| Refrigerant | R290 |
| Mode | Heating & cooling |
| Heating performance | |
| Heating capacity | 19–41.8 kW |
| Max heating output (low temp) | 41.8 kW at A-7/W35 |
| COP (heating) | 4.6 at A7/W35 |
| SCOP (heating) | 4.7 at W35 |
| Operating range (air) | -22 to 40 °C |
| Heating flow temperature | up to 70 °C |
| Cooling performance | |
| Cooling capacity | 30.4 kW |
| Max cooling output (high temp) | 30.4 kW at A35/W18 |
| EER (cooling) | 3.4 at A35/W18 |
| Cooling flow temperature | from 7 °C |
| Electrical, acoustic and physical | |
| Electrical supply | 380-415V (Three Phase) |
| Sound power level | 54 dB(A) (Sound Power LW(A)) |
| Dimensions (H×W×D) | 1764 × 1970 × 1000 mm |
| Operational Weight | 600 kg |
Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.