Product data sheetheatpumpdatabase.com

Ebac Ebac 5kW Graphite + Black
Model code: H1A05GB-GB
✓ BUS eligible✓ MCS listedAir Source (ASHP)ResidentialHeating only
Heating capacity
9.72 kW
SCOP
4.91
W35
COP
4.99
A7/W35
Max flow temp
60°C
Sound power
64.5 dB(A)
Refrigerant
R32
Boiler Upgrade Scheme
✓ BUS eligible
Listed on the Ofgem BUS Product Eligibility List (24 Sep 2026).
PEL certificate: MCS HP0369/01
Grant also needs an MCS-certified installer and a qualifying system design.
MCS certification
✓ MCS listed
| General | |
|---|---|
| Heat pump type | Air Source (ASHP) |
| Application | Residential |
| Refrigerant | R32 |
| Mode | Heating only |
| Heating performance | |
| Heating capacity | 9.72 kW |
| Max heating output (low temp) | 5.6 kW at A-7/W35 |
| COP (heating) | 4.99 at A7/W35 |
| SCOP (heating) | 4.91 at W35 |
| Operating range (air) | -20 to 35 °C |
| Heating flow temperature | 15–60 °C |
| Electrical, acoustic and physical | |
| Power input | 1 kW |
| Electrical supply | 220-240V (Single Phase) |
| Sound power level | 64.5 dB(A) (Sound Power LW(A)) |
| Dimensions (H×W×D) | 800 × 1042 × 435 mm |
| Operational Weight | 90 kg |
Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.