ES Heat Pumps AW EVI-M

Model code: AW 30-EVI-M
✓ BUS eligible✓ MCS listedAir Source (ASHP)CommercialHeating & cooling
Heating capacity
12.2–29.4 kW
SCOP
4.21
W35
COP
4.43
A7/W35
Max flow temp
60°C
Sound power
66 dB(A)
Refrigerant
R410A

Boiler Upgrade Scheme

✓ BUS eligible

Listed on the Ofgem BUS Product Eligibility List (24 Sep 2026).

PEL certificate: MCS HP0358/01

Grant also needs an MCS-certified installer and a qualifying system design.

MCS certification

✓ MCS listed

Certificate: MCS HP0358/01

General
Heat pump typeAir Source (ASHP)
ApplicationCommercial
RefrigerantR410A
ModeHeating & cooling
Heating performance
Heating capacity12.2–29.4 kW
Max heating output (low temp)28.7 kW at A7/W35
COP (heating)4.43 at A7/W35
SCOP (heating)4.21 at W35
Operating range (air)-30 to 55 °C
Heating flow temperature20–60 °C
Cooling performance
Cooling capacity26.8 kW
Max cooling output (high temp)21.2 kW at A35/W7
EER (cooling)2.84 at A35/W7
Cooling flow temperaturefrom 7 °C
Electrical, acoustic and physical
Electrical supply380-415V (Three Phase)
Sound power level66 dB(A) (Sound Power LW(A))
Dimensions (H×W×D)1447 × 1295 × 455 mm
Operational Weight191 kg

Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.