Product data sheetheatpumpdatabase.com
Gree Versati II split
Model code: GRS-CQ8.0Pd/NaE-K
Air Source (ASHP)ResidentialHeating & cooling
Heating capacity
8 kW
COP
4.5
A7/W35
Max flow temp
55°C
Refrigerant
R410A
Boiler Upgrade Scheme
Not found on the Ofgem BUS Product Eligibility List.
MCS certification
No MCS listing recorded.
| General | |
|---|---|
| Heat pump type | Air Source (ASHP) |
| Application | Residential |
| Refrigerant | R410A |
| Mode | Heating & cooling |
| Heating performance | |
| Heating capacity | 8 kW |
| Max heating output (low temp) | 7.6 kW at A7/W45 |
| COP (heating) | 4.5 at A7/W35 |
| Operating range (air) | -20 to 35 °C |
| Heating flow temperature | 25–55 °C |
| Cooling performance | |
| Cooling capacity | 7.8 kW |
| Max cooling output (high temp) | 6.3 kW at A35/W7 |
| EER (cooling) | 2.7 at A35/W7 |
| Cooling flow temperature | 7–25 °C |
| Electrical, acoustic and physical | |
| Electrical supply | 220-240V (Single Phase) |
| Dimensions (H×W×D) | 787 × 980 × 360 mm |
| Operational Weight | 80 kg |
Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.