← Back to product pageFree data sheet, no subscription
heatpumpdatabase
Product data sheetheatpumpdatabase.com

GT R290 DC Inverter

Model code: GT-SKR030KBDC-M290
✓ BUS eligible✓ MCS listedAir Source (ASHP)ResidentialHeating & cooling
Heating capacity
3.65–10.38 kW
SCOP
4.49
W35
COP
4.3
A7/W35
Max flow temp
75°C
Refrigerant
R290

Boiler Upgrade Scheme

✓ BUS eligible

Listed on the Ofgem BUS Product Eligibility List (24 Sep 2026).

PEL certificate: MCS HP0371/03

Grant also needs an MCS-certified installer and a qualifying system design.

MCS certification

✓ MCS listed

Certificate: MCS HP0371/03

General
Heat pump typeAir Source (ASHP)
ApplicationResidential
RefrigerantR290
ModeHeating & cooling
Heating performance
Heating capacity3.65–10.38 kW
Max heating output (low temp)8.4 kW at A2/W55
COP (heating)4.3 at A7/W35
SCOP (heating)4.49 at W35
Operating range (air)-25 to 43 °C
Heating flow temperature10–75 °C
Cooling performance
Cooling capacity8.1 kW
Max cooling output (high temp)8.1 kW at A35/W7
EER (cooling)2.8 at A35/W7
Cooling flow temperaturefrom 10 °C
Electrical, acoustic and physical
Electrical supply220-240V (Single Phase)
Dimensions (H×W×D)795 × 1100 × 460 mm
Operational Weight85 kg

Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.