← Back to product pageFree data sheet, no subscription
heatpumpdatabase
Product data sheetheatpumpdatabase.com

GT R32 Inverter

Model code: GT-SKR030KBDC-M32
Air Source (ASHP)ResidentialHeating & cooling
Heating capacity
4.5–10.66 kW
COP
4.4
A7/W35
Max flow temp
60°C
Refrigerant
R32

Boiler Upgrade Scheme

Not found on the Ofgem BUS Product Eligibility List.

MCS certification

No MCS listing recorded.

General
Heat pump typeAir Source (ASHP)
ApplicationResidential
RefrigerantR32
ModeHeating & cooling
Heating performance
Heating capacity4.5–10.66 kW
Max heating output (low temp)7.71 kW at A-7/W35
COP (heating)4.4 at A7/W35
Operating range (air)-20 to 43 °C
Heating flow temperature10–60 °C
Cooling performance
Cooling capacity8.45 kW
Max cooling output (high temp)8.45 kW at A35/W7
EER (cooling)2.85 at A35/W7
Cooling flow temperaturefrom 10 °C
Electrical, acoustic and physical
Electrical supply220-240V (Single Phase)
Dimensions (H×W×D)795 × 1010 × 410 mm
Operational Weight72 kg

Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.