← Back to product pageFree data sheet, no subscription
heatpumpdatabase
Product data sheetheatpumpdatabase.com

GT R32 Inverter - Split Type

Model code: GT-SKR050KBDC-S32
Air Source (ASHP)ResidentialHeating & cooling
Heating capacity
8.6–20.3 kW
COP
4.4
A7/W35
Max flow temp
60°C
Refrigerant
R32

Boiler Upgrade Scheme

Not found on the Ofgem BUS Product Eligibility List.

MCS certification

No MCS listing recorded.

General
Heat pump typeAir Source (ASHP)
ApplicationResidential
RefrigerantR32
ModeHeating & cooling
Heating performance
Heating capacity8.6–20.3 kW
Max heating output (low temp)14.93 kW at A-7/W35
COP (heating)4.4 at A7/W35
Operating range (air)-20 to 43 °C
Heating flow temperature10–60 °C
Cooling performance
Cooling capacity18.7 kW
Max cooling output (high temp)18.7 kW at A35/W7
EER (cooling)2.9 at A35/W7
Cooling flow temperaturefrom 10 °C
Electrical, acoustic and physical
Electrical supply380-415V (Three Phase)
Dimensions (H×W×D)1280 × 1165 × 470 mm
Operational Weight122 kg

Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.