Product data sheetheatpumpdatabase.com

Haier AW142HVGHA
Model code: AW142HVGHA
✓ MCS listedAir Source (ASHP)ResidentialHeating & cooling
Heating capacity
14 kW
SCOP
4.8
W35
COP
4.95
A7/W35
Max flow temp
80°C
Sound power
64 dB(A)
Refrigerant
R290
Boiler Upgrade Scheme
Not found on the Ofgem BUS Product Eligibility List.
MCS certification
✓ MCS listed
Certificate: 24.01.019 AW142HVGHA
| General | |
|---|---|
| Heat pump type | Air Source (ASHP) |
| Application | Residential |
| Refrigerant | R290 |
| Mode | Heating & cooling |
| Heating performance | |
| Heating capacity | 14 kW |
| Max heating output (low temp) | 13.5 kW at A7/W55 |
| COP (heating) | 4.95 at A7/W35 |
| SCOP (heating) | 4.8 at W35 |
| Operating range (air) | -25 to 48 °C |
| Heating flow temperature | 20–80 °C |
| Cooling performance | |
| Cooling capacity | 13.5 kW |
| Max cooling output (high temp) | 12 kW at A35/W7 |
| EER (cooling) | 4.3 |
| Electrical, acoustic and physical | |
| Electrical supply | 220-240V (Single Phase) |
| Sound power level | 64 dB(A) (Sound Power LW(A)) |
| Dimensions (H×W×D) | 880 × 1250 × 460 mm |
| Operational Weight | 140 kg |
Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.