Product data sheetheatpumpdatabase.com

Heliotherm Air Heat Pump Split Design
Model code: HP20L-M-BC
Air Source (ASHP)ResidentialHeating & cooling
Heating capacity
5.1–19.1 kW
COP
6.6
A7/W27
Max flow temp
62°C
Sound power
43 dB(A)
Refrigerant
Not stated
Boiler Upgrade Scheme
Not found on the Ofgem BUS Product Eligibility List.
MCS certification
No MCS listing recorded.
| General | |
|---|---|
| Heat pump type | Air Source (ASHP) |
| Application | Residential |
| Refrigerant | Not stated |
| Mode | Heating & cooling |
| Heating performance | |
| Heating capacity | 5.1–19.1 kW |
| Max heating output (low temp) | 16.2 kW at A-7/W34 |
| COP (heating) | 6.6 at A7/W27 |
| Operating range (air) | -25 to 45 °C |
| Heating flow temperature | up to 62 °C |
| Cooling performance | |
| Cooling capacity | 18.2 kW |
| Max cooling output (high temp) | 18.2 kW at A35/W7 |
| EER (cooling) | 4.2 at A35/W18 |
| Electrical, acoustic and physical | |
| Sound power level | 43 dB(A) (Sound Power LW(A)) |
| Dimensions (H×W×D) | 1700 × 600 × 670 mm |
| Operational Weight | 213 kg |
Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.