← Back to product pageFree data sheet, no subscription
heatpumpdatabase
Product data sheetheatpumpdatabase.com

Heliotherm Air Heat Pump Split Design

Model code: HP08L-M-BC
✓ BUS eligible✓ MCS listedAir Source (ASHP)ResidentialHeating & cooling
Heating capacity
2.4–10.3 kW
COP
5.9
A7/W27
Max flow temp
62°C
Sound power
40 dB(A)
Refrigerant
Not stated

Boiler Upgrade Scheme

✓ BUS eligible

Listed on the Ofgem BUS Product Eligibility List (24 Sep 2026).

PEL certificate: BBA 0136/27

Grant also needs an MCS-certified installer and a qualifying system design.

MCS certification

✓ MCS listed

General
Heat pump typeAir Source (ASHP)
ApplicationResidential
RefrigerantNot stated
ModeHeating & cooling
Heating performance
Heating capacity2.4–10.3 kW
Max heating output (low temp)8.8 kW at A-7/W34
COP (heating)5.9 at A7/W27
Operating range (air)-25 to 45 °C
Heating flow temperatureup to 62 °C
Cooling performance
Cooling capacity10.3 kW
Max cooling output (high temp)10 kW at A35/W7
EER (cooling)4.2 at A35/W18
Electrical, acoustic and physical
Sound power level40 dB(A) (Sound Power LW(A))
Dimensions (H×W×D)1700 × 600 × 670 mm
Operational Weight203 kg

Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.