Product data sheetheatpumpdatabase.com

Hisa HR290 Gen 2
Model code: HR290-004-1PH
Air Source (ASHP)ResidentialHeating & cooling
Heating capacity
1.39–5.78 kW
COP
5.36
A7/W35
Max flow temp
75°C
Sound power
51 dB(A)
Refrigerant
R290
Boiler Upgrade Scheme
Not found on the Ofgem BUS Product Eligibility List.
MCS certification
No MCS listing recorded.
| General | |
|---|---|
| Heat pump type | Air Source (ASHP) |
| Application | Residential |
| Refrigerant | R290 |
| Mode | Heating & cooling |
| Heating performance | |
| Heating capacity | 1.39–5.78 kW |
| Max heating output (low temp) | 5.27 kW at A7/W55 |
| COP (heating) | 5.36 at A7/W35 |
| Operating range (air) | -25 to 35 °C |
| Heating flow temperature | 20–75 °C |
| Cooling performance | |
| Cooling flow temperature | 5–25 °C |
| Electrical, acoustic and physical | |
| Power input | 2.1 kW |
| Electrical supply | 220-240V (Single Phase) |
| Sound power level | 51 dB(A) (Sound Power LW(A)) |
| Dimensions (H×W×D) | 660 × 1100 × 438 mm |
| Operational Weight | 83 kg |