Product data sheetheatpumpdatabase.com

Hitachi Yutaki M
Model code: RHUE-5AHN-HM
✓ BUS eligible✓ MCS listedAir Source (ASHP)ResidentialHeating only
Heating capacity
15 kW
COP
4.01
A7/W35
Max flow temp
60°C
Refrigerant
R410A
Boiler Upgrade Scheme
✓ BUS eligible
Listed on the Ofgem BUS Product Eligibility List (24 Sep 2026).
PEL certificate: MCS HP0032/10
Grant also needs an MCS-certified installer and a qualifying system design.
MCS certification
✓ MCS listed
Certificate: MCS HP0032/10
| General | |
|---|---|
| Heat pump type | Air Source (ASHP) |
| Application | Residential |
| Refrigerant | R410A |
| Mode | Heating only |
| Heating performance | |
| Heating capacity | 15 kW |
| Max heating output (low temp) | 10.9 kW at A-7/W35 |
| COP (heating) | 4.01 at A7/W35 |
| Operating range (air) | -20 to 40 °C |
| Heating flow temperature | up to 60 °C |
| Electrical, acoustic and physical | |
| Electrical supply | 380-415V (Three Phase) |
| Dimensions (H×W×D) | 1480 × 1250 × 444 mm |
| Operational Weight | 160 kg |
Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.