← Back to product pageFree data sheet, no subscription
heatpumpdatabase
Product data sheetheatpumpdatabase.com

Hitachi Yutaki M

Model code: Yutaki M 14kW
Air Source (ASHP)ResidentialHeating & cooling
Heating capacity
16.7 kW
SCOP
4.48
W35
COP
4.71
A7/W35
Max flow temp
60°C
Sound power
65 dB(A)
Refrigerant
R410A

Boiler Upgrade Scheme

Not found on the Ofgem BUS Product Eligibility List.

MCS certification

No MCS listing recorded.

General
Heat pump typeAir Source (ASHP)
ApplicationResidential
RefrigerantR410A
ModeHeating & cooling
Heating performance
Heating capacity16.7 kW
Max heating output (low temp)11.2 kW at A-7/W55
COP (heating)4.71 at A7/W35
SCOP (heating)4.48 at W35
Operating range (air)-25 to 35 °C
Heating flow temperature20–60 °C
Cooling performance
Cooling capacity17 kW
EER (cooling)3.22 at A35/W7
Electrical, acoustic and physical
Power input2.97 kW
Electrical supply220-240V (Single Phase)
Sound power level65 dB(A) (Sound Power LW(A))
Dimensions (H×W×D)1380 × 1252 × 370 mm
Operational Weight133 kg

Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.