← Back to product pageFree data sheet, no subscription
heatpumpdatabase
Product data sheetheatpumpdatabase.com

Hitachi Yutaki S

Model code: Yutaki S 6kW
Air Source (ASHP)ResidentialHeating & cooling
Heating capacity
1.85–8.6 kW
SCOP
4.5
W35
COP
4.8
A7/W35
Max flow temp
60°C
Sound power
63 dB(A)
Refrigerant
R32

Boiler Upgrade Scheme

Not found on the Ofgem BUS Product Eligibility List.

MCS certification

No MCS listing recorded.

General
Heat pump typeAir Source (ASHP)
ApplicationResidential
RefrigerantR32
ModeHeating & cooling
Heating performance
Heating capacity1.85–8.6 kW
Max heating output (low temp)5 kW at A-7/W55
COP (heating)4.8 at A7/W35
SCOP (heating)4.5 at W35
Operating range (air)-20 to 43 °C
Heating flow temperature20–60 °C
Cooling performance
Cooling capacity6 kW
EER (cooling)3.6
Electrical, acoustic and physical
Power input1.21 kW
Electrical supply220-240V (Single Phase)
Sound power level63 dB(A) (Sound Power LW(A))
Dimensions (H×W×D)629 × 799 × 300 mm
Operational Weight44 kg

Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.