← Back to product pageFree data sheet, no subscription
heatpumpdatabase
Product data sheetheatpumpdatabase.com

Hitachi Yutaki S

Model code: Yutaki S 20kW
Air Source (ASHP)CommercialHeating & cooling
Heating capacity
9–25.5 kW
SCOP
3.88
W35
COP
4.3
A7/W35
Max flow temp
60°C
Sound power
73 dB(A)
Refrigerant
R410A

Boiler Upgrade Scheme

Not found on the Ofgem BUS Product Eligibility List.

MCS certification

No MCS listing recorded.

General
Heat pump typeAir Source (ASHP)
ApplicationCommercial
RefrigerantR410A
ModeHeating & cooling
Heating performance
Heating capacity9–25.5 kW
Max heating output (low temp)14.5 kW at A-7/W55
COP (heating)4.3 at A7/W35
SCOP (heating)3.88 at W35
Operating range (air)-25 to 43 °C
Heating flow temperature20–60 °C
Cooling performance
Cooling capacity16.4 kW
EER (cooling)3.12
Electrical, acoustic and physical
Power input4.65 kW
Electrical supply220-240V (Single Phase)
Sound power level73 dB(A) (Sound Power LW(A))
Dimensions (H×W×D)1380 × 950 × 370 mm
Operational Weight137 kg

Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.