← Back to product pageFree data sheet, no subscription
heatpumpdatabase
Product data sheetheatpumpdatabase.com

Keyter Pacifica Pro 6100

Model code: KWEB 6100 I V S4D
Air Source (ASHP)CommercialHeating & cooling
Heating capacity
114.3 kW
COP
4.69
A7/W35
Max flow temp
75°C
Refrigerant
R290

Boiler Upgrade Scheme

Not found on the Ofgem BUS Product Eligibility List.

MCS certification

No MCS listing recorded.

General
Heat pump typeAir Source (ASHP)
ApplicationCommercial
RefrigerantR290
ModeHeating & cooling
Heating performance
Heating capacity114.3 kW
Max heating output (low temp)114.3 kW at A7/W35
COP (heating)4.69 at A7/W35
Operating range (air)-20 to 50 °C
Heating flow temperature20–75 °C
Cooling performance
Cooling capacity97.8 kW
Max cooling output (high temp)97.8 kW at A35/W7
EER (cooling)3.55 at A35/W7
Electrical, acoustic and physical
Electrical supply380-415V (Three Phase)
Dimensions (H×W×D)2375 × 3920 × 1100 mm
Operational Weight1462 kg

Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.