← Back to product pageFree data sheet, no subscription
heatpumpdatabase
Product data sheetheatpumpdatabase.com

LG Therma V R290 Monobloc 16kW

Model code: HM161HF.UB60
✓ BUS eligible✓ MCS listedAir Source (ASHP)ResidentialHeating & cooling
Heating capacity
16 kW
SCOP
5.11
W35
COP
4.3
A7/W35
Max flow temp
75°C
Sound power
52 dB(A)
Refrigerant
R290

Boiler Upgrade Scheme

✓ BUS eligible

Listed on the Ofgem BUS Product Eligibility List (24 Sep 2026).

PEL certificate: 011-1W0689_34

Grant also needs an MCS-certified installer and a qualifying system design.

MCS certification

✓ MCS listed

Certificate: 011-1W0689_34

General
Heat pump typeAir Source (ASHP)
ApplicationResidential
RefrigerantR290
ModeHeating & cooling
Heating performance
Heating capacity16 kW
Max heating output (low temp)13.8 kW at A2/W35
COP (heating)4.3 at A7/W35
SCOP (heating)5.11 at W35
Operating range (air)-28 to 35 °C
Heating flow temperature15–75 °C
Cooling performance
Cooling capacity12.5 kW
Max cooling output (high temp)12.5 kW at A35/W7
EER (cooling)2.95 at A35/W7
Electrical, acoustic and physical
Power input3.7 kW
Electrical supply220-240V (Single Phase)
Sound power level52 dB(A) (Sound Power LW(A))
Dimensions (H×W×D)1019 × 1560 × 520 mm
Operational Weight181 kg

Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.