Product data sheetheatpumpdatabase.com

Mitsubishi Electric Hydrodan
Model code: EHWT17D-MHEDW
Water Source (WSHP)ResidentialHeating only
Heating capacity
1.2–11.3 kW
COP
9.2
W20/W35
Max flow temp
60°C
Sound power
38 dB(A)
Refrigerant
R32
Boiler Upgrade Scheme
Not found on the Ofgem BUS Product Eligibility List.
MCS certification
No MCS listing recorded.
| General | |
|---|---|
| Heat pump type | Water Source (WSHP) |
| Application | Residential |
| Refrigerant | R32 |
| Mode | Heating only |
| Heating performance | |
| Heating capacity | 1.2–11.3 kW |
| Max heating output (low temp) | 7.8 kW at W25/W45 |
| COP (heating) | 9.2 at W20/W35 |
| Operating range (air) | 10 to 30 °C |
| Heating flow temperature | 20–60 °C |
| Electrical, acoustic and physical | |
| Electrical supply | 220-240V (Single Phase) |
| Sound power level | 38 dB(A) (Sound Power LW(A)) |
| Dimensions (H×W×D) | 1750 × 595 × 680 mm |
| Operational Weight | 166 kg |
Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.