← Back to product pageFree data sheet, no subscription
heatpumpdatabase
Product data sheetheatpumpdatabase.com

Ochsner AIR HAWK 518 C11A

Model code: 287310V
✓ BUS eligible✓ MCS listedAir Source (ASHP)ResidentialHeating and Cooling
Heating capacity
3.3–13.1 kW
SCOP
5.04
W35
COP
4.82
A7/W35
Max flow temp
65°C
Sound power
53 dB(A)
Refrigerant
R32

Boiler Upgrade Scheme

✓ BUS eligible

Listed on the Ofgem BUS Product Eligibility List (24 Sep 2026).

PEL certificate: BBA 0037/30

Grant also needs an MCS-certified installer and a qualifying system design.

MCS certification

✓ MCS listed

Certificate: BBA 0037/30

General
Heat pump typeAir Source (ASHP)
ApplicationResidential
RefrigerantR32
ModeHeating and Cooling
Heating performance
Heating capacity3.3–13.1 kW
Max heating output (low temp)9 kW at A-7/W34
COP (heating)4.82 at A7/W35
SCOP (heating)5.04 at W35
Operating range (air)-22 to 43 °C
Heating flow temperatureup to 65 °C
Cooling performance
Cooling capacity7.97 kW
Max cooling output (high temp)6.38 kW at A35/W7
EER (cooling)3.84 at A35/W18
SEER (cooling)5.43 at W18
Electrical, acoustic and physical
Electrical supply380-415V (Three Phase)
Sound power level53 dB(A) (Sound Power LW(A))
Dimensions (H×W×D)1261 × 1292 × 965 mm
Operational Weight88 kg

Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.