← Back to product pageFree data sheet, no subscription
heatpumpdatabase
Product data sheetheatpumpdatabase.com

Ochsner AIR MILAN 1016 C11A CM1

Model code: 50286811-SET02
Air Source (ASHP)ResidentialHeating and Cooling
Heating capacity
4.4–12 kW
SCOP
4.9
W35
COP
4.8
A7/W35
Max flow temp
70°C
Sound power
59 dB(A)
Refrigerant
R290

Boiler Upgrade Scheme

Not found on the Ofgem BUS Product Eligibility List.

MCS certification

No MCS listing recorded.

General
Heat pump typeAir Source (ASHP)
ApplicationResidential
RefrigerantR290
ModeHeating and Cooling
Heating performance
Heating capacity4.4–12 kW
Max heating output (low temp)12 kW at A-7/W34
COP (heating)4.8 at A7/W35
SCOP (heating)4.9 at W35
Operating range (air)-25 to 46 °C
Heating flow temperatureup to 70 °C
Cooling performance
Cooling capacity12 kW
Max cooling output (high temp)12 kW at A35/W18
EER (cooling)4 at A35/W18
SEER (cooling)4.8 at W18
Electrical, acoustic and physical
Electrical supply380-415V (Three Phase)
Sound power level59 dB(A) (Sound Power LW(A))
Dimensions (H×W×D)1018 × 1270 × 560 mm
Operational Weight140 kg

Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.