← Back to product pageFree data sheet, no subscription
heatpumpdatabase
Product data sheetheatpumpdatabase.com

Ochsner GMSW

Model code: GMSW 7 HK plus
Ground Source (GSHP)ResidentialHeating and Cooling
Heating capacity
7.1 kW
SCOP
4.45
W35
COP
4.3
B0/W35
Max flow temp
65°C
Sound power
41 dB(A)
Refrigerant
R407C

Boiler Upgrade Scheme

Not found on the Ofgem BUS Product Eligibility List.

MCS certification

No MCS listing recorded.

General
Heat pump typeGround Source (GSHP)
ApplicationResidential
RefrigerantR407C
ModeHeating and Cooling
Heating performance
Heating capacity7.1 kW
Max heating output (low temp)6.1 kW at B0/W60
COP (heating)4.3 at B0/W35
SCOP (heating)4.45 at W35
Operating range (air)-6 to 20 °C
Heating flow temperatureup to 65 °C
Cooling performance
Cooling capacity8.2 kW
Max cooling output (high temp)5.2 kW at B25/W7
EER (cooling)4.8 at B25/W18
Electrical, acoustic and physical
Electrical supply380-415V (Three Phase)
Sound power level41 dB(A) (Sound Power LW(A))
Dimensions (H×W×D)1150 × 600 × 650 mm
Operational Weight115 kg

Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.