Product data sheetheatpumpdatabase.com

Ochsner GMSW
Model code: GMSW 27 plus
Ground Source (GSHP)CommercialHeating only
Heating capacity
26.1 kW
SCOP
4.81
W35
COP
4.5
B0/W35
Max flow temp
68°C
Sound power
60 dB(A)
Refrigerant
R410A
Boiler Upgrade Scheme
Not found on the Ofgem BUS Product Eligibility List.
MCS certification
No MCS listing recorded.
| General | |
|---|---|
| Heat pump type | Ground Source (GSHP) |
| Application | Commercial |
| Refrigerant | R410A |
| Mode | Heating only |
| Heating performance | |
| Heating capacity | 26.1 kW |
| Max heating output (low temp) | 22.2 kW at B0/W60 |
| COP (heating) | 4.5 at B0/W35 |
| SCOP (heating) | 4.81 at W35 |
| Operating range (air) | -6 to 20 °C |
| Heating flow temperature | up to 68 °C |
| Electrical, acoustic and physical | |
| Electrical supply | 380-415V (Three Phase) |
| Sound power level | 60 dB(A) (Sound Power LW(A)) |
| Dimensions (H×W×D) | 1150 × 600 × 650 mm |
| Operational Weight | 265 kg |
Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.