Product data sheetheatpumpdatabase.com

Ochsner GMWW
Model code: GMWW 14 plus VX
Water Source (WSHP)ResidentialHeating only
Heating capacity
12.3 kW
SCOP
6.43
W35
COP
5.8
W10/W35
Max flow temp
65°C
Sound power
50 dB(A)
Refrigerant
R410A
Boiler Upgrade Scheme
Not found on the Ofgem BUS Product Eligibility List.
MCS certification
No MCS listing recorded.
| General | |
|---|---|
| Heat pump type | Water Source (WSHP) |
| Application | Residential |
| Refrigerant | R410A |
| Mode | Heating only |
| Heating performance | |
| Heating capacity | 12.3 kW |
| Max heating output (low temp) | 10.9 kW at W10/W60 |
| COP (heating) | 5.8 at W10/W35 |
| SCOP (heating) | 6.43 at W35 |
| Operating range (air) | 6 to 25 °C |
| Heating flow temperature | up to 65 °C |
| Electrical, acoustic and physical | |
| Electrical supply | 220-240V (Single Phase) |
| Sound power level | 50 dB(A) (Sound Power LW(A)) |
| Dimensions (H×W×D) | 1150 × 400 × 650 mm |
| Operational Weight | 120 kg |