← Back to product pageFree data sheet, no subscription
heatpumpdatabase
Product data sheetheatpumpdatabase.com

Ochsner GMWW

Model code: GMWW 17 plus VX
Water Source (WSHP)ResidentialHeating only
Heating capacity
16.6 kW
SCOP
6.52
W35
COP
5.9
W10/W35
Max flow temp
65°C
Sound power
51 dB(A)
Refrigerant
R410A

Boiler Upgrade Scheme

Not found on the Ofgem BUS Product Eligibility List.

MCS certification

No MCS listing recorded.

General
Heat pump typeWater Source (WSHP)
ApplicationResidential
RefrigerantR410A
ModeHeating only
Heating performance
Heating capacity16.6 kW
Max heating output (low temp)13.8 kW at W10/W60
COP (heating)5.9 at W10/W35
SCOP (heating)6.52 at W35
Operating range (air)6 to 25 °C
Heating flow temperatureup to 65 °C
Electrical, acoustic and physical
Electrical supply220-240V (Single Phase)
Sound power level51 dB(A) (Sound Power LW(A))
Dimensions (H×W×D)1150 × 600 × 650 mm
Operational Weight132 kg

Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.