← Back to product pageFree data sheet, no subscription
heatpumpdatabase
Product data sheetheatpumpdatabase.com

Panasonic Aquarea M Series

Model code: WH-WXG16ME8
✓ BUS eligible✓ MCS listedAir Source (ASHP)ResidentialHeating & cooling
Heating capacity
16 kW
SCOP
4.2
W35
COP
4.89
A7/W35
Max flow temp
75°C
Sound power
53 dB(A)
Refrigerant
R290

Boiler Upgrade Scheme

✓ BUS eligible

Listed on the Ofgem BUS Product Eligibility List (24 Sep 2026).

PEL certificate: 011-1W0924_1

Grant also needs an MCS-certified installer and a qualifying system design.

MCS certification

✓ MCS listed

Certificate: 011-1W0924_1

General
Heat pump typeAir Source (ASHP)
ApplicationResidential
RefrigerantR290
ModeHeating & cooling
Heating performance
Heating capacity16 kW
Max heating output (low temp)16 kW at A-7/W55
COP (heating)4.89 at A7/W35
SCOP (heating)4.2 at W35
Operating range (air)-25 to 43 °C
Heating flow temperature25–75 °C
Cooling performance
Cooling capacity9 kW
Max cooling output (high temp)9 kW at A35/W7
EER (cooling)3.61 at A35/W7
Electrical, acoustic and physical
Electrical supply380-415V (Three Phase)
Sound power level53 dB(A) (Sound Power LW(A))
Dimensions (H×W×D)1520 × 1200 × 430 mm
Operational Weight165 kg

Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.