← Back to product pageFree data sheet, no subscription
heatpumpdatabase
Product data sheetheatpumpdatabase.com

Panasonic Aquarea T-CAP F Generation (bi-bloc / All in One)

Model code: WH-UX09FE5
✓ MCS listedAir Source (ASHP)ResidentialHeating & cooling
Heating capacity
9 kW
COP
4.84
A7/W35
Max flow temp
55°C
Refrigerant
R410A

Boiler Upgrade Scheme

Not found on the Ofgem BUS Product Eligibility List.

MCS certification

✓ MCS listed

Certificate: MCS HP0086/49; MCS HP0086/62

General
Heat pump typeAir Source (ASHP)
ApplicationResidential
RefrigerantR410A
ModeHeating & cooling
Heating performance
Heating capacity9 kW
Max heating output (low temp)9 kW at A-7/W35
COP (heating)4.84 at A7/W35
Operating range (air)-20 to 35 °C
Heating flow temperature25–55 °C
Cooling performance
Cooling capacity7 kW
Max cooling output (high temp)7 kW at A35/W7
EER (cooling)3.17 at A35/W7
Cooling flow temperature5–20 °C
Electrical, acoustic and physical
Electrical supply220-240V (Single Phase)
Dimensions (H×W×D)1340 × 900 × 320 mm
Operational Weight101 kg

Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.