← Back to product pageFree data sheet, no subscription
heatpumpdatabase
Product data sheetheatpumpdatabase.com

Panasonic Aquarea T-CAP H Generation (bi-bloc / All in One)

Model code: WH-UX09HE5
✓ MCS listedAir Source (ASHP)ResidentialHeating & cooling
Heating capacity
9 kW
SCOP
4.6
W35
COP
4.84
A7/W35
Max flow temp
60°C
Sound power
68 dB(A)
Refrigerant
R410A

Boiler Upgrade Scheme

Not found on the Ofgem BUS Product Eligibility List.

MCS certification

✓ MCS listed

Certificate: MCS HP0086/109; MCS HP0086/86

General
Heat pump typeAir Source (ASHP)
ApplicationResidential
RefrigerantR410A
ModeHeating & cooling
Heating performance
Heating capacity9 kW
Max heating output (low temp)9 kW at A-7/W35
COP (heating)4.84 at A7/W35
SCOP (heating)4.6 at W35
Operating range (air)-28 to 35 °C
Heating flow temperature20–60 °C
Cooling performance
Cooling capacity7 kW
Max cooling output (high temp)7 kW at A35/W7
EER (cooling)3.17 at A35/W7
Cooling flow temperature5–20 °C
Electrical, acoustic and physical
Electrical supply220-240V (Single Phase)
Sound power level68 dB(A) (Sound Power LW(A))
Dimensions (H×W×D)1340 × 900 × 320 mm
Operational Weight101 kg

Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.