← Back to product pageFree data sheet, no subscription
heatpumpdatabase
Product data sheetheatpumpdatabase.com

Sabroe HitemHP 112 S

Water Source (WSHP)CommercialHeating only
Heating capacity
600 kW
COP
4.4
W50/W103
Max flow temp
103°C
Refrigerant
R600a

Boiler Upgrade Scheme

Not found on the Ofgem BUS Product Eligibility List.

MCS certification

No MCS listing recorded.

General
Heat pump typeWater Source (WSHP)
ApplicationCommercial
RefrigerantR600a
ModeHeating only
Heating performance
Heating capacity600 kW
COP (heating)4.4 at W50/W103
Operating range (air)45 to 50 °C
Heating flow temperature65–103 °C
Electrical, acoustic and physical
Power input136 kW
Electrical supplyNot stated
Dimensions (H×W×D)2400 × 1300 × 6500 mm
Operational Weight5880 kg

Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.