Samsung EHS Mono R290 Outdoor Pump Integrated
Model code: AE080CXYBEK/EU
✓ BUS eligible✓ MCS listedAir Source (ASHP)ResidentialHeating & cooling

Heating capacity
8.6 kW
SCOP
4.66
W35
COP
4.91
A7/W35
Max flow temp
75°C
Sound power
59 dB(A)
Refrigerant
R290
Boiler Upgrade Scheme
✓ BUS eligible
Listed on the Ofgem BUS Product Eligibility List (24 Sep 2026).
PEL certificate: 011-1W0687_3
Grant also needs an MCS-certified installer and a qualifying system design.
MCS certification
✓ MCS listed
Certificate: 011-1W0687_3
| General | |
|---|---|
| Heat pump type | Air Source (ASHP) |
| Application | Residential |
| Refrigerant | R290 |
| Mode | Heating & cooling |
| Heating performance | |
| Heating capacity | 8.6 kW |
| Max heating output (low temp) | 7.45 kW at A-7/W55 |
| COP (heating) | 4.91 at A7/W35 |
| SCOP (heating) | 4.66 at W35 |
| Operating range (air) | -25 to 35 °C |
| Heating flow temperature | 15–75 °C |
| Cooling performance | |
| Cooling capacity | 8 kW |
| Max cooling output (high temp) | 8 kW at A35/W18 |
| EER (cooling) | 3.9 at Not stated |
| Cooling flow temperature | 5–25 °C |
| Electrical, acoustic and physical | |
| Power input | 1.63 kW |
| Electrical supply | 220-240V (Single Phase) |
| Sound power level | 59 dB(A) (Sound Power LW(A)) |
| Dimensions (H×W×D) | 850 × 1270 × 500 mm |
| Operational Weight | 125 kg |
Test conditions: A = outdoor air °C, W = flow water °C (e.g. A7/W35 = 7°C air, 35°C flow). Compare COP and SCOP only at the same conditions.